Product Overview
The HLP demineralizers are the most popular tap water-powered devices that meet all the requirements of any modern laboratory in terms of demand for water suitable for analytical and instrumental purposes. Obtained water with a conductivity below 0.06 µS/cm meets the requirements of PN-EN ISO 3696:1999, ASTM, CLSI, EP. The resulting water can be used for instrumental analysis AAS, ICP / MS, IC, HPLC, GC (depending on the model).
Cat. no.: DH-0010-00
Features
– Fed by tap water.
– Water purification levels:
• sediment pre-filter 5µm,
• integrated module (sediment-carbon-softening),
• reverse osmosis,
• double demineralization on a mixed ionex resin,
• UV lamp 254 nm,
• microfiltration cascade capsule 0,45/0,2μm.
– Efficiency min. 10-12 dm3/h.
– Membrane pump is included.
– Demineralized water conductivity 0,06 μS/cm.
– Two independ water intake points:
• Second purity class (PN-EN ISO 3696:1999, ASTM, CLSI).
• First purity class (PN-EN ISO 3696:1999, EP).
– Tank 10 dm3.
– Obtained water may be used for instrumental analyses AAS, ICP/MS, IC, HPLC, GC, bacteria cultures, biochemical analyses and for general-purpose research.
– Fed by cold water: 5-40°C.
– Power supply: 230V/50Hz.
Functions monitoring the device:
• The device is equipped with a microprocessor control and measurement system that includes:
- LCD display screen 2x16 characters
- conductometer measuring conductivity and temperature of purified water (measured in µS/cm or MOhm),
- reading values compensated and uncompensated thermally,
- timer displaying current date and time,
- alarm informing about necessity to replace sediment filter and module A,
- alarm informing about necessity to replace ionex resins,
- alarm informing about necessity to replace microfiltration capsule,
- alarm informing about necessity to replace UV lamp,
- menu in English, Russian, Spanish or German,
- maintenance deadlines preview,
- built-in RS 232 connector for personal computers,
- individual adjustment of maintenance frequency and alarm levels.
• Software.
• Built-in manometer measuring feed water pressure.
Functions protecting the device:
• Pomp shutdown when:
- feed water pressure is too low (lack of feed water) – low-pressure sensor,
- the tank is full – high-pressure sensor.
Feed water parameters:
- Conductivity  1200 μS/cm
- Pressure  3,0 bar
- Temperature: 5-40ºC
- Hardness  250 mg CaCO3/dm3
- Fe  0,2 mg/dm3
Required connections:
- cold tap water connection ½” lub ¾”,
- 230V socket, - drain.
Package Included:
Sediment prefilter 5µm EO-005-10
Module A2 EO-MA-12
Module H6 EJ-5000-0
MF capsule 0,2µm EM-SP-20
UV lamp radiator 254nm